Dykes at 100 to 300 m under the Jos Plateau: what the magnetic anomaly should look like
A 2025 aeromagnetic study puts mineralised dykes 100 to 300 m deep under Nigeria's Younger Granite province. We model those bodies with fibub's magnetic anomaly modeller and ask what susceptibility, width and flight-line spacing the claim needs.
Nigeria’s Jos Plateau is built of Jurassic “Younger Granite” ring complexes, the rocks that made the country a tin and niobium producer. A 2025 paper in Frontiers in Earth Science reprocesses the regional aeromagnetic grid over that province and places mineralised structures 100 to 300 m below the surface, with magnetic anomalies of a few nT up to about 66 nT. A depth from a magnetic map is never measured directly: it is read off the shape of an anomaly, so it is worth asking what shape such a body would actually make. That is what a forward model is for, and this article runs the paper’s own numbers through the magnetic anomaly modeller modeller. For the same ground from other angles, try the gravity survey corrections and the VES inversion.
The paper in brief
The authors take the national aeromagnetic grid over the Younger Granite region: flight lines 500 m apart, tie lines 5,000 m apart, flown at 80 m nominal height (the paper also quotes a 120 m average), in blocks of 55 by 55 km. They remove the main field, then apply the usual chain of enhancements: reduction to the magnetic equator, a Butterworth band-pass, the analytic signal, source parameter imaging (SPI), Euler deconvolution and a 3D inversion.
The results they report are: magnetic highs above about 66 nT and lows below about −5.3 nT, with mixed anomalies of +7 to +66 nT and −1 to −22 nT over three target areas; SPI depths of 83.4 to 110 m and 92 to 167 m for a shallow magnetic layer and 174 to 450 m for a deeper one; Euler solutions with structural index 0 (the index for a thin sheet) clustering at 100 to 300 m, which they read as dykes; and a 3D inversion whose mineralised bodies sit mostly between 100 and 500 m, with susceptibilities kept below 0.004 SI.
Checked with the tools
We cannot refit their grid: the maps are images and the readings are not published. What the tool can do is the other direction, which is just as useful: take the bodies the paper proposes and compute the anomaly they must make. If the modelled anomaly is far smaller than the one measured, or far narrower than the flight-line spacing, the interpretation needs more than the data can give.
The model is a vertical thin dyke, 30 m thick and 2,000 m down dip, at a range of depths, in a main field of 33,500 nT with an inclination of 0° — the Jos Plateau lies within a degree or two of the magnetic dip equator, and the paper works with an idealised reduction to the magnetic equator. The field strength, the dyke’s thickness and the 0.02 SI susceptibility of a magnetite-bearing granite are our assumptions; the depths, the sensor height and the anomaly sizes are the paper’s.
Step 1: near the magnetic equator a dyke reads as a low, not a high. With the field almost horizontal, the induced magnetisation lies across the dyke, and the total-field anomaly over the body is negative with only a whisper of a high on the flanks (Figure 1). Our 30 m dyke gives a low of −13.1 nT with its top 100 m down, −8.6 nT at 200 m and −6.3 nT at 300 m. That sits squarely inside the paper’s reported −1 to −22 nT band, so the negative anomalies need nothing unusual.
Step 2: the 66 nT highs cannot come from a thin dyke. The anomaly is strictly proportional to susceptibility and to thickness, so the arithmetic is easy. To reach 22 nT at 150 m depth, our 30 m dyke needs χ = 0.042 SI, ten times the 0.004 SI ceiling used in the paper’s own 3D inversion, or a thickness of 63 m at 0.02 SI. To reach 66 nT it needs χ = 0.126 SI or a thickness of 190 m — no longer a dyke. Swap the dyke for a 400 by 400 m plug (a ring-complex stock) running from 150 m down to 2,000 m, and the same 0.02 SI susceptibility gives a peak-to-trough anomaly of 43.4 nT, rising to 56.9 nT with the top at 100 m. The paper’s largest anomalies therefore point to wide, plug-like bodies, while the thin-sheet Euler solutions can only own the small ones.
| Check | Paper | Our model (tool’s maths) |
|---|---|---|
| Anomaly of a dyke 100 to 300 m deep | −1 to −22 nT lows | −13.1 nT (100 m) to −6.3 nT (300 m), 30 m thick, χ 0.02 SI |
| A +66 nT anomaly from a thin sheet | read as dykes at 100 to 300 m | needs χ 0.126 SI or 190 m thickness at 150 m depth |
| A +66 nT anomaly from a plug | 3D inversion bodies 100 to 500 m | 43.4 nT peak to trough for a 400 m plug at 150 m, 56.9 nT at 100 m |
| Susceptibility ceiling | below 0.004 SI in the inversion | 0.004 SI gives only about 2 nT for the 30 m dyke at 150 m |
Step 3: the flight lines are too far apart for the shallow class. The width of the modelled low, measured at half its depth, is 1.6 to 1.8 times the distance from the sensor to the top of the body — a handy rule in itself, since it turns round to depth below the sensor ≈ 0.57 × width. For a top 100 m down and a sensor 120 m up that width is 399 m; at 200 m depth it is 559 m and at 450 m it is 923 m (Figure 2). With flight lines 500 m apart, an anomaly from the shallow 83 to 167 m class is sampled by one line, sometimes two. Depths for that class are therefore along-line estimates with no control across line, and the 174 to 450 m class is the one the survey geometry can really support.
Step 4: the flight height matters more than it looks. Flying at 120 m instead of 80 m weakens our 150 m dyke from −12.5 nT to −10.4 nT, a 16 % loss, because the sensor-to-body distance grows from 230 to 270 m. A paper that quotes both heights is quoting two different amplitude scales, and any susceptibility taken from amplitude alone inherits that 16 %.
Step 5: remanence rearranges the picture. Younger Granite magnetite can carry a frozen-in magnetisation. Give the same 150 m dyke a remanence of 2 A/m at an inclination of 60° (our assumption) and the induced magnetisation of 0.533 A/m is swamped: the Koenigsberger ratio is Q = 3.75, the low deepens to −38.5 nT and a high of +11.4 nT appears 117 m to one side. Remanence is the simplest way to get strong, lopsided, mixed-sign anomalies out of modest bodies, and it is the one thing a susceptibility-only inversion cannot see.
How we made the graphs
The charts and every number come from scripts/blog-figures/jos-plateau-younger-granite-dyke-depth-magnetic-anomaly.mjs in fibub’s public code. It calls profile, magnetisation and koenigsberger from src/lib/sci/magnetic.ts, the maths behind the magnetic anomaly modeller modeller: the thin dyke is a closed-form integral of a sheet of two-dimensional dipoles, and the plug is the surface-pole solution for a uniformly magnetised prism.
From the paper: the depths (100, 150, 200, 300 and 450 m), the sensor heights (80 and 120 m), the 500 m flight-line spacing, the anomaly sizes (22 and 66 nT) and the 0.004 SI susceptibility ceiling. Our assumptions: the main field (33,500 nT, inclination 0°, declination 0°), the dyke (30 m thick, vertical, 2,000 m down dip), the plug (400 by 400 m, top to 2,000 m), the 0.02 SI susceptibility and the remanence (2 A/m at 60°). Widths are read off a profile sampled every metre from −1,000 to +1,000 m. Nothing here is the paper’s own data.
How we test the maths
On every change to fibub, tests/sci.mjs runs tests/sci-tools/magnetic-anomaly.mjs, which pins all four bodies against independent NumPy and SciPy models in a field of 50,000 nT at inclination 60°, declination 10°, with a profile azimuth of 30°:
- the sphere must match a dipole potential differentiated by central differences to within 1e-6 nT (values such as 46.1430 nT at the station 0 m);
- the thin dyke must match point dipoles integrated over strike and down dip by nested quadrature to within 1e-4 nT (81.3840 nT at 45 m);
- the prism must match Gauss-Legendre sums of point dipoles to within 1e-6 nT (753.4137 nT at 0 m), and a 1 m wide, very long, very deep prism must equal a vertical thin dyke to 0.1 %;
- physics checks: a sphere at the magnetic pole is symmetric with its peak at 2μ₀m/(4πz³), and a small cube far away equals a dipole of the same volume to 0.1 %.
- New with this article: the dyke and plug models above, sampled as the tool samples them, must give lows of −10.44 nT (30 m dyke), −21.92 nT (63 m dyke) and −37.68 nT (400 m plug) with a high of +5.74 nT.
Check it yourself
On the magnetic anomaly modeller page:
- In The Earth’s field, set Field strength F (nT) to 33500, Inclination I (°, down +) to 0, Declination D (°, east +) to 0, Profile direction (° from north) to 0 and Sensor height (m) to 120. Set Profile from (m) -800 to (m) 800.
- Choose Shape thin dyke or sheet (2D). Set Susceptibility χ (SI) to 0.02, Position along profile (m) to 0, Depth to top (m) to 150, Thickness (m) to 30, Dip (°, toward + profile; 90 vertical) to 90 and Down-dip extent (m) to 2000.
- The headline reads Dyke: high +0.0 nT at 0 m, low −10.4 nT at 0 m, and Peak to trough shows 10.5 nT. That is the whole anomaly of a 30 m dyke at the paper’s shallow depth.
- Change Thickness (m) to 63: the low goes to −21.9 nT and Peak to trough to 22.0 nT, matching the strongest negative anomaly the paper reports.
- Switch Shape to vertical prism (3D box) with Width along profile (m) 400, Length across profile (m) 400, Depth to top (m) 150 and Depth to bottom (m) 2000: the low is −37.7 nT, the high +5.7 nT and Peak to trough 43.4 nT. A plug does what a dyke cannot.
- Tick Add remanent magnetisation and enter Remanence Mr (A/m) 2, Its inclination (°) 60, Its declination (°) 0 on the 30 m dyke: Magnetisation shows Koenigsberger ratio Q = 3.75 and the anomaly becomes lopsided.
What researchers can use it for
- Sanity-check a depth estimate before you publish it. Model the body you think you have, measure the width of the modelled anomaly, and compare it with your station or line spacing: with the magnetic anomaly modeller modeller that takes a minute.
- Decide a survey’s line spacing from the target. Width at half amplitude is about 1.7 times the sensor-to-top distance, so a 100 m target needs lines a few hundred metres apart, not 500 m.
- Turn an amplitude into a susceptibility, honestly. The anomaly is linear in χ and in thickness, so one modelled profile gives the whole family; quote the thickness you assumed.
- Test whether remanence is needed. If no plausible susceptibility reaches the measured amplitude, remanence or a wider body is the answer; the modeller gives you the Koenigsberger ratio as you type.
- Compare methods on one line. Model the magnetic profile, then the gravity with the gravity survey corrections tool and the layering with the VES inversion tool, and draw the result with the cross-section profile tool.
The fine print
- Our anomalies are modelled, not measured. The paper’s grid and maps are not published as numbers, so no fit to its data is possible.
- The main field, the body sizes and the susceptibility are our assumptions; the paper does not state its field inclination, so our “reads as a low” result follows from the magnetic equator assumption. Reduced-to-pole or reduced-to-equator maps change the sign convention.
- The tool models a body with uniform magnetisation and a flat ground surface. Real ring complexes are neither.
- Euler deconvolution and SPI depths carry their own window and window-size uncertainties that no forward model can repair.
Sources
- Usman, A. O., Nomeh, J. S., Abraham, E. M. and Azuoko, G.-B. (2025), Uncovering the hidden mineral treasure of the Jurassic Younger Granite region of Nigeria using integrated magnetic geophysical techniques, Frontiers in Earth Science 13: 1568232, doi:10.3389/feart.2025.1568232. Licence CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/, version of record, recorded in the publisher's own Crossref deposit), checked 2026-11-24. Values used here: flight-line spacing 500 m and tie lines 5000 m; flight height given as 80 m nominal and 120 m average; grid blocks 55 by 55 km; high magnetic values above about 66 nT and low values below about -5.3 nT, with mixed anomalies of +7 to +66 nT and -1 to -22 nT; source-parameter-imaging depths 83.4 to 110 m, 92 to 167 m (shallow) and 174 to 450 m (deep); Euler deconvolution with structural index 0 clustering at 100 to 300 m and read as dykes; 3D inversion structures mostly at 100 to 500 m with susceptibilities kept below 0.004 SI; analytic-signal threshold 0.075 nT/m.
- Dipole, thin-sheet and uniformly magnetised prism fields are standard potential-field results (Blakely, R. J., 1995, Potential Theory in Gravity and Magnetic Applications, Cambridge University Press); fibub's module is written from the physics and pinned against independent NumPy and SciPy models.
If you are an author or publisher and want a credit or a passage changed or removed, tell us and we will act quickly.