Murriyang cryogenic phased array feed: HI noise and beam checked
A 72-beam cooled receiver on the 64 m Parkes dish maps hydrogen in the LMC. We rebuild its noise, beam and column-density limit with the radiometer equation.
A big radio dish normally looks at one patch of sky at a time. A phased array feed (PAF) puts a grid of small antennas at the focus and combines their signals in a computer to form many beams at once, so the dish maps the sky many times faster. A 2026 paper describes the first spectral-line results from a cooled (cryogenic) PAF on Murriyang, the 64 m Parkes telescope in Australia: 72 beams, a low-noise receiver, and maps of the neutral hydrogen (HI) in the Large Magellanic Cloud (LMC) and the galaxy NGC 6744. This article rebuilds the paper’s stated noise levels and beam size from four numbers with the radio telescope calculator, then turns the noise into a hydrogen column density as the hydrogen line analyser does. To change between frequency and velocity widths, use the redshift calculator.
The paper in brief
Neutral hydrogen gives out a faint radio line at 1420.4 MHz, the 21 cm line. Its strength tells you how much gas lies along each line of sight and its Doppler shift tells you how the gas moves. Mapping it over big areas is slow, so survey speed matters.
The new receiver covers 0.7 to 2 GHz and is cooled so that its system temperature (Tsys, the total noise of receiver and sky, written as a temperature) is about 17 K at 1.4 GHz. The team reports an aperture efficiency, the share of the dish’s area that really collects signal, of about 0.7, and a main-beam efficiency of about 0.8. Each of the 72 beams is about 0.24° wide, and neighbours are 0.14° apart.
They mapped an 8° × 8° field of the LMC in 66 minutes with 49 pointings of about 80 s, in 5 kHz channels (1.1 km/s). They expected 28 mK of noise per beam and 18 mK in the final cube, and measured about 18 mK, a column density noise of 3.6 × 10¹⁶ atoms per cm². A short look at NGC 6744 gave a total HI flux of 5.07 ± 0.25 Jy MHz, in line with the older HIPASS survey’s 4.88 ± 0.27. The paper also tests new ways of removing radio interference and continuum, which we do not check here.
Checked with the tools
This is a recomputation from values stated in the paper’s text, with the dish’s published 64 m diameter. Nothing here is the paper’s data.
Step 1: gain and SEFD. With a 64 m dish and an efficiency of 0.7, the tool’s maths gives an effective area of 2252 m² and a gain of 0.816 K/Jy: a source of 1 jansky (Jy, 10⁻²⁶ W m⁻² Hz⁻¹) raises the antenna temperature by 0.816 K. Dividing Tsys by the gain gives the system equivalent flux density (SEFD), the source brightness that would equal the system’s own noise: 20.8 Jy.
Step 2: noise per beam. The radiometer equation says the noise falls with the square root of bandwidth times time: σ = SEFD / √(2 × B × t), the 2 for the two polarisations. For a 5 kHz channel and 80 s this is 23.3 mJy, or 19.0 mK of antenna temperature. Survey work quotes noise as a sky brightness, so divide by the efficiency. With the aperture efficiency (17 / 0.7 = 24.3 K) we get 27.2 mK; with the paper’s measured 25 K exactly, 27.95 mK, the paper’s 28 mK. With the main-beam efficiency (21 K) it would be only 23.8 mK. So the paper’s 28 mK uses the more cautious aperture value (Figure 1).
Step 3: from one beam to the map. Neighbouring beams and pointings overlap, so each spot in the map is measured about 2.5 times. Noise falls by √2.5: 27.95 / 1.58 = 17.7 mK, the paper’s “about 18 mK” (17.2 mK if you start from the rounded 17 K and 0.7).
Step 4: column density. For optically thin gas, the column density is 1.823 × 10¹⁸ times the area under the line in K km/s, the formula in the Hydrogen line analyser. One 5 kHz channel at 1420.4 MHz is 1.055 km/s wide (radio convention). With 18 mK and 1.1 km/s, as the paper rounds them, the limit is 3.61 × 10¹⁶ cm⁻², the paper’s value; with 17.2 mK and 1.055 km/s it is 3.30 × 10¹⁶.
Step 5: beam size. A tapered dish has a half-power beam of about 1.2 λ/D. At 1420 MHz (λ = 21.1 cm) that is 0.227°, or 13.6 arcmin, a little under the paper’s 0.24° (Figure 2). A PAF beam is formed electronically and its effective taper differs from a horn’s, so a few per cent wider is expected. The 0.14° spacing is about 0.6 of a beam, which is why beams overlap.
Step 6: the NGC 6744 flux in familiar units. At 1420.4 MHz, 1 MHz of bandwidth is 211.06 km/s of velocity. The cryoPAF’s 5.07 ± 0.25 Jy MHz is therefore 1070 ± 53 Jy km/s, and HIPASS’s 4.88 Jy MHz is 1030 Jy km/s, the 1031 the paper quotes. The two agree within their errors.
| Check | Paper | Our tool result |
|---|---|---|
| Tsys over aperture efficiency | 25 K | 24.3 K (17 ÷ 0.7) |
| Noise per beam, 80 s, 5 kHz | 28 mK | 27.95 mK (from 25 K), 27.2 mK (from 17 K and 0.7) |
| Noise in the LMC cube | about 18 mK | 17.7 mK (√2.5 weighting) |
| Column density noise | 3.6 × 10¹⁶ cm⁻² | 3.61 × 10¹⁶ (18 mK, 1.1 km/s) |
| Beam at 1.4 GHz | about 0.24° | 0.227° (1.2 λ/D) |
| NGC 6744 HI flux | 5.07 Jy MHz | 1070 Jy km/s |
How we made the graphs
The charts and every number come from scripts/blog-figures/parkes-murriyang-cryogenic-phased-array-feed-hi-sensitivity.mjs in fibub’s public code. It calls scope from src/lib/sci/radiotel.ts (gain, SEFD, beam width and the radiometer equation), the maths behind the radio telescope calculator, and velRadio, F0 and columnDensity from src/lib/astro/hline.ts, the maths behind the hydrogen line analyser.
Tsys, both efficiencies, the beam width and spacing, the 80 s pointings, the 5 kHz channels, the 2.5 weighting and the NGC 6744 fluxes come from the paper’s text. The 64 m diameter is the telescope’s published size. Treating each 80 s pointing as one beam’s integration time is our reading of the paper’s noise budget; it reproduces the stated 28 mK.
How we test the maths
On every change to fibub, tests/sci.mjs checks the radio telescope maths:
- A 100 m dish with 70 % efficiency must give a gain of 1.991 K/Jy, as the Green Bank Telescope quotes, an SEFD of 10.05 Jy for Tsys 20 K, and a beam of 8.83 arcmin at 1.4 GHz.
- An array of 27 dishes must use N(N−1) = 702 pairs in the radiometer equation.
- New with this article, in
tests/sci-tools/radio-telescope-calculator.mjs: a 64 m dish with efficiency 0.7 and Tsys 17 K at 1420 MHz must give 0.816 K/Jy, an SEFD of 20.8 Jy, 23.3 mJy of noise in 80 s and 5 kHz (19.0 mK, which is Tsys/√(2Bt)), and a 13.6 arcmin beam.
Check it yourself
On the radio telescope calculator:
- Type 1420 in Frequency (MHz), 64 in Dish diameter (m), 0.7 in Aperture efficiency and 17 in System temperature (K). Leave Number of dishes at 1 and Polarisations on Two.
- Type 0.005 in Bandwidth (MHz) (one 5 kHz channel) and 80 in Integration time, with the unit set to seconds.
- The headline reads Noise 23.3 mJy after 80 seconds. Gain shows 0.816 K/Jy, System equivalent flux density 20.8 Jy and Beam width 13.6 arcmin.
- Multiply the noise by the gain and divide by 0.7: 0.0233 × 0.816 ÷ 0.7 = 0.0272 K, the 27 to 28 mK per beam of the paper.
- Change Integration time to 1 minute: the noise becomes 26.9 mJy. Four times the time halves the noise, which is why 72 beams at once matter so much for survey speed.
What researchers can use it for
- Plan an HI survey: put in your dish, Tsys and channel width, and find the time per pointing for a target noise in mK with the radio telescope calculator.
- Turn noise into a column density limit with the 1.823 × 10¹⁸ factor, as the hydrogen line analyser does for a measured line.
- Check a paper’s noise budget quickly: if the radiometer equation and the stated Tsys disagree, look for the efficiency or weighting that was used.
- Convert line widths and fluxes between MHz, km/s and redshift with the redshift calculator (radio convention).
- Teach why cooled receivers and many beams change what a telescope can do: halve Tsys and you need a quarter of the time.
The fine print
- This is a recomputation from the paper’s rounded values, not a reanalysis of its data.
- The tool’s beam uses the 1.2 λ/D rule for a tapered dish; a PAF’s formed beams can be a little wider or narrower and change shape across the field.
- The radiometer equation is the ideal case. Real data lose a little to channel weighting, interference flagging and baseline fitting.
- The column density assumes optically thin gas; in the densest LMC clouds the true value is higher.
Sources
- Staveley-Smith, L. et al. (2026), Murriyang cryogenic phased array feed: spectral-line results and noise-reduction methods, Publications of the Astronomical Society of Australia 43: e057, doi:10.1017/pasa.2026.10164. Licence CC BY 4.0 (Creative Commons Attribution), checked on the Cambridge Core page, 2026-11-24. Values used here: system temperature about 17 K at 1.4 GHz; aperture efficiency about 0.7 and main-beam efficiency about 0.8; Tsys over efficiency 25 K (aperture) and 21 K (main beam); up to 72 dual-polarisation beams spaced 0.14° apart, each about 0.24° wide at 1.4 GHz; band 0.7 to 2 GHz; LMC map of 49 pointings of about 80 s, 5 kHz (1.1 km/s) channels, mean spatial weight 2.5, 28 mK per beam and about 18 mK in the cube, column density noise 3.6 × 10¹⁶ cm⁻²; NGC 6744 flux 5.07 ± 0.25 Jy MHz against 4.88 ± 0.27 Jy MHz (1031 ± 57 Jy km/s) from HIPASS.
- Dish diameter of 64 m: the telescope's published size (CSIRO, Murriyang, the Parkes radio telescope).
- Radiometer equation and the HI column density factor 1.823 × 10¹⁸ cm⁻² per K km/s: Wilson, Rohlfs and Hüttemeister (2013), Tools of Radio Astronomy, Springer.