Salmonella in sausage batter: rebuilding a published z-value from four D-values
A study heated Salmonella Typhimurium in alheira sausage batter at four temperatures. We refit its Bigelow line with fibub's F-value calculator and get its z-value, its 200-minute reference D and its 9-second kill at 70 °C back.
Heat kills bacteria at a steady rate on a log scale, and two numbers describe the whole process: the D-value, the minutes at one temperature that kill 90 % of them, and the z-value, the extra degrees that make the killing ten times faster. A study of alheira, a Portuguese smoked sausage made from a raw meat-and-bread batter, measured D-values for Salmonella Typhimurium in that batter at four temperatures and fitted a z-value to them. Those four pairs of numbers are all in the paper’s text, which makes the whole result something anybody can rebuild in a browser: this article refits them with the f-value calculator, gets the paper’s z-value, reference D and 70 °C cooking time back, and then shows where the fit is weakest. For the canning convention of F₀ use the autoclave F0, and to turn a cooking step into a written control use the HACCP plan builder.
The paper in brief
The authors inoculated alheira batter with Salmonella Typhimurium at about 7.0 to 7.5 log CFU/g (CFU means colony-forming units, the countable living cells) and heated 10 g bags at 54, 57, 60 and 63 °C, taking samples over 100 minutes at the coolest temperature and over 5 minutes at the hottest. Survivor counts at each temperature fell along a straight line on a log scale, which is the first-order or log-linear model:
- log₁₀ N(t) = log₁₀ N₀ − t ÷ D
Fitting that line at each temperature gave D-values of 26.52, 7.936, 3.663 and 0.348 minutes. The paper also reports the same thing as an exponential death rate, which is simply 1 ÷ D: 0.038, 0.126, 0.273 and 2.872 log CFU per minute.
The second step is the Bigelow model, a straight line through those four D-values on a log scale:
- log₁₀ D = log₁₀ D_ref − (T − T_ref) ÷ z
With a reference temperature of 50 °C the paper reports log₁₀ D_ref = 2.302 (about 200 minutes per log at 50 °C) and z = 5.016 °C, with R² = 0.947. From that line it concludes that a 7-log reduction at 70 °C needs only 9.0 seconds.
Checked with the tools
Everything below is a recomputation from the four D-values printed in the paper. No data were simulated and nothing was read off a figure.
Step 1: the Bigelow line. Typing the four temperature and D-value pairs into the z-value from D-values card gives z = 5.0153 °C and R² = 0.9469, against the paper’s 5.016 °C and 0.947. The same fit puts log₁₀ D at 50 °C at 2.3020, so D_ref = 200.4 minutes, against the paper’s 2.302 and “200 min”. The agreement is exact to the digits the paper prints, which means the paper’s fit is the ordinary least-squares line and nothing else (Figure 1).
Step 2: the 70 °C claim. Extending that line to 70 °C gives D = 0.02061 minutes, which rounds to the paper’s 0.021. Seven log reductions therefore need 7 × D = 0.1443 minutes, or 8.66 seconds. The paper says 9.0 seconds, the same number rounded from its own slightly different z. So the headline cooking figure checks out: at a centre temperature of 70 °C, this Salmonella in this batter is gone in under ten seconds.
Step 3: where the fit is weak. R² of 0.947 sounds high, but with only four points it hides a real miss. The fitted line puts D at 63 °C at 0.513 minutes, while the measured value is 0.348. In practical terms, a 7-log kill at 63 °C takes 3.59 minutes by the line and 2.44 minutes by the measured D: a 47 % difference at the hottest temperature tested. The 63 °C D-value also carries the paper’s largest standard error (0.763 on an exponential death rate of 2.872, about 27 %), which is what you expect when a whole log-linear curve has to be caught inside five minutes. Figure 2 turns the line into the number a cook or a process engineer wants, the minutes for a 7-log kill at each centre temperature.
Step 4: a real cook is not a hold. A sausage centre does not jump to a temperature and sit there, so the lethality has to be added up over the heating curve. This is the general method: at every instant the lethal rate is L = 10^((T − T_ref) ÷ z), and F is the area under L against time. We put an assumed heating curve through the tool’s profile card: a gentle cook in which the centre creeps up to 58.1 °C after 30 minutes and then cools (our curve, not measured, and not from the paper). With the paper’s z and a 70 °C reference it gives F = 0.043 minutes, which is 2.08 log reductions — far short of seven, even though the sausage spent half an hour in the “nearly cooked” range (Figure 3). A z-value as small as 5 °C means almost all of the killing happens in the last few degrees.
| Check | Paper says | The tool gives |
|---|---|---|
| z-value | 5.016 °C (SE 0.839) | 5.0153 °C |
| Bigelow R² | 0.947 | 0.9469 |
| log₁₀ D at 50 °C | 2.302 (SE 0.304) | 2.3020 (D = 200.4 min) |
| D at 70 °C | about 0.021 min | 0.02061 min |
| Time for 7 logs at 70 °C | 9.0 s | 8.66 s |
| Exponential death rates (1 ÷ D) | 0.038, 0.126, 0.273, 2.872 | 0.0377, 0.1260, 0.2730, 2.8736 |
| D at 63 °C from the line | not given | 0.513 min, against the measured 0.348 min |
How we made the graphs
The charts and every number in this article come from scripts/blog-figures/salmonella-alheira-sausage-batter-bigelow-z-value-recomputed.mjs in fibub’s public code. It calls zValue (the Bigelow least-squares fit, which also returns D at any temperature), fNeeded (F = D × log reductions) and fProfile (the general method by the trapezoid rule) from src/lib/sci/thermproc.ts, the maths behind the f-value calculator.
The four temperatures and four D-values are the paper’s, quoted from its running text. The heating curve in Figure 3 is our assumption: a first-order rise towards 59 °C read every two minutes, with a linear cool-down. The 70 °C reference temperature in that calculation is our choice, so that F can be read directly as log reductions of this organism.
How we test the maths
On every change to fibub, tests/sci.mjs runs tests/sci-tools/thermal-process-calculator.mjs, which pins the tool against NumPy and SciPy:
- A made-up five-point survivor curve must give D = 2.9559926 min, log₁₀ N₀ = 5.9973723 and R² = 0.99993701, as
numpy.polyfitdoes. - Made-up D-values of 20, 6.5, 2 and 0.62 min at 110, 115, 120 and 125 °C must give z = 9.9249706 °C, R² = 0.99988829 and D = 1.5456807 min at 121.1 °C.
- A made-up 13-point retort profile must give F₀ = 27.356058 min by the trapezoid rule, matching
numpy.trapezoid, and 36.409945 min when the reference is changed to 120 °C with z = 8 °C. - New with this article: the paper’s four D-values must give z = 5.01526 °C, R² = 0.94690, D = 200.436 min at 50 °C and D = 0.0206132 min at 70 °C, and
fNeededmust turn that into 0.144292 min for seven log reductions.
Check it yourself
On the F-value calculator:
- In the Reference card, set Reference temperature, T_ref (°C) to 50 and leave z-value (°C) as it is for now.
- In z-value from D-values, paste the paper’s four pairs, one per line: 54, 26.52; 57, 7.936; 60, 3.663; 63, 0.348.
- It shows z = 5.02 °C, with D at 50 °C 200 min, R² 0.9469 and D-values 4.
- Now change Reference temperature, T_ref (°C) to 70. The same card’s D at 70 °C fact changes to about 0.0206 min.
- Press Use this z and D above and below. The z-value (°C) box becomes 5.02 and D at T_ref (min) fills with 0.021, the rounded D at 70 °C.
- In F needed for a log reduction, type 10000000 in Starting count, N₀ and 1 in Count wanted, N. It reads F = 0.147 min (7 log reductions), that is 8.8 seconds. Replace the rounded 0.021 with 0.0206 and it reads F = 0.144 min, our 8.66 seconds.
- Change Count wanted, N to 1e-3 to ask for ten logs instead: F becomes about 0.206 min, or 12 seconds.
What researchers can use it for
- Refit a published z-value from the D-values in a table, and see its R² and the D it predicts at the temperature you actually cook at.
- Check a cooking claim such as “70 °C for 15 seconds”, by comparing it with 7 × D at that temperature from the paper you are relying on.
- Turn a logger file into lethality: paste a time-and-temperature profile from a thermocouple into the profile card and get F and the log reductions by the general method, with any reference temperature and z.
- Teach why z matters: a z of 5 °C and a z of 10 °C give the same D at the reference temperature but completely different answers five degrees away.
- Separate the pathogen from the convention: F₀ (121.1 °C, z = 10 °C) is for spores in cans, not for Salmonella in a sausage; the autoclave F0 does the canning convention, this tool does any reference you set.
The fine print
- The paper is a short conference paper from an electronic Foods conference, with four D-values and no survivor-count table, so we could refit the Bigelow line but not the primary curves behind it.
- Its z-value carries a standard error of 0.839 °C. Put z = 4.2 or 5.9 °C through the same sums and the time for a 7-log kill at 70 °C moves by roughly a factor of two.
- The 54 and 57 °C D-values come from heating that lasted 100 and 50 minutes. Long holds at those temperatures can let heat-shocked cells adapt, which the log-linear model does not allow for.
- The heating curve in Figure 3 and its 70 °C reference are ours. Nothing in it is a measurement of alheira.
- D- and z-values belong to one organism in one food. Do not carry these numbers to another product.
Sources
- Coelho-Fernandes, S., Cadavez, V. and Gonzales-Barron, U. (2022), Thermal Inactivation Kinetics of Salmonella typhimurium in alheira Sausage Batter, Biology and Life Sciences Forum 18(1): 44, doi:10.3390/foods2022-13001. Licence CC BY 4.0, checked on the MDPI article page and in the Crossref record, 2026-11-24. Values used here, all from the paper's running text: treatment temperatures 54, 57, 60 and 63 °C; D-values 26.52, 7.936, 3.663 and 0.348 min; exponential death rates 0.038, 0.126, 0.273 and 2.872 log CFU/min; primary-model R² 0.914 to 0.987; Bigelow R² 0.947; log D at the 50 °C reference 2.302 (standard error 0.304), that is about 200 min; z-value 5.016 °C (standard error 0.839); a 7-log reduction at 70 °C in 9.0 s with D about 0.021 min; inoculum 7.0 to 7.5 log CFU/g.
- D-value, the Bigelow model and the general method: Stumbo, C. R. (1973), Thermobacteriology in Food Processing, 2nd ed., Academic Press; Bigelow, W. D. (1921), Journal of Infectious Diseases 29: 528-536.
If you are an author or publisher and want a credit or a passage changed or removed, tell us and we will act quickly.