Home / Courses / IIT JAM Physics / Practice / Raman spectroscopy

Raman spectroscopy

Atomic and molecular physics · 6 questions and templates for IIT JAM Physics, in order from warm-up to top rank. Check each answer, then read the full solution.

Loading questions… (they need JavaScript; nothing you type is sent anywhere)

Written questions with solutions

The same questions as a list, so you can print them or read without the practice box. Templates (fresh numbers) appear only in the practice box above.

  1. MCQWarm-up

    The horizontal axis of a Raman spectrum is usually labelled "Raman shift (cm−1)". This quantity is
    1. the wavenumber of the scattered light
    2. the wavelength difference between laser and scattered light, in cm
    3. the wavenumber of the laser minus the wavenumber of the scattered light
    4. the frequency of the laser divided by c
    Answer and solution

    Answer: C

    Raman shift Δν~=ν~laser−ν~scattered (with ν~=1/λ). It equals the energy given to (Stokes, positive) or taken from (anti-Stokes, negative) the molecule, in wavenumbers, and does not depend on which laser is used.

    Why people get this wrong: A difference of wavelengths is not proportional to an energy difference; only wavenumbers subtract simply.

  2. MCQStandard

    A sample shows a band in the scattered light. Which test best decides whether the band is Raman scattering or fluorescence?
    1. Change the laser wavelength: a Raman band moves with the laser (same shift in cm−1), a fluorescence band stays at the same wavelength
    2. Measure the band's width: Raman bands are always broader
    3. Cool the sample: Raman bands disappear
    4. Raise the laser power: only fluorescence grows
    Answer and solution

    Answer: A

    Raman scattering keeps a fixed energy difference from the laser, so if the laser moves by 10 nm the band moves by about the same amount. Fluorescence comes from a fixed excited state and stays at the same absolute wavelength. Both grow with laser power; Raman bands are usually narrower; Stokes Raman lines survive cooling.

    Why people get this wrong: Intensity tests do not separate them; the dependence on excitation wavelength does.

  3. MSQStandard

    Which of these can be measured with Raman spectroscopy?
    1. The vibration of N2 molecules in air
    2. The rotational constant of CO2
    3. The optical phonon of silicon
    4. The bending fundamental of CO2 at 667 cm−1
    Answer and solution

    Answer: A, B, C

    N2's stretch changes its polarisability (Raman active, 2331 cm−1), though it has no IR band. CO2 has an anisotropic polarisability, so it has a rotational Raman spectrum (lines 4B apart, B=0.390 cm−1). Silicon's 520 cm−1 optical phonon is the standard Raman calibration line. The CO2 bend is antisymmetric under inversion (Πu): IR active, Raman inactive.

    Why people get this wrong: CO2 has no rotational microwave spectrum but does have a rotational Raman spectrum.

  4. MCQExam level

    A polymer is excited at 785.0 nm. Its strong band has a Raman shift of 1001 cm−1. The corresponding anti-Stokes line is at
    1. 852.0 nm
    2. 727.8 nm
    3. 722.0 nm
    4. 784.0 nm
    Answer and solution

    Answer: B

    ν~laser=107/785.0=12738.9 cm−1. Anti-Stokes: 12738.9+1001=13739.9 cm−1, so λ=107/13739.9=727.8 nm. (The Stokes line is at 107/11737.9=852.0 nm.)

    Why people get this wrong: 852.0 nm is the Stokes line; anti-Stokes lies on the blue side.

← All topics · Timed mock test →