Copper-67 and copper-64 from accelerator neutrons: what the eight-hour separation costs

A 2025 paper makes Cu-67 and Cu-64 with accelerator neutrons and separates them from zinc in about eight hours. We put its half-lives, activities and impurity ratios through fibub's decay calculator.

Copper-67 is one of the most wanted radionuclides in cancer research: it emits beta particles that travel about 3 mm in tissue and gamma rays you can image, and its chemistry is the same as that of copper-64, the PET tracer, so the same molecule can be used to find a tumour and then treat it. The problem has always been making it. A 2025 paper in Frontiers in Nuclear Medicine makes both isotopes by firing deuterons at a carbon target, using the neutrons that come off to irradiate zinc oxide, and then separating the copper from the zinc by boiling the zinc away. Every number in that route has a clock attached, and the decay calculator is the tool that reads the clock. For the chains that feed and follow these nuclides, see the decay chain simulator simulator, and for the counting statistics behind activities this small, the counting statistics helper helper.

The paper in brief

Deuterons at 41 and 52 MeV hit a 10 mm carbon target; the neutrons produced go on into a small pellet of enriched zinc oxide. Fast neutrons knock a proton out of zinc-68 or zinc-67 to leave copper-67, and zinc-64 gives copper-64. The great advantage is that the unwanted companions are few: a 3 minute irradiation of 0.363 g of enriched zinc-68 oxide gave 1.23 kBq of copper-67 at the end of irradiation with only 2.9 Bq of zinc-65, and the authors’ calculations sit within 20 % of every measured value.

Then the chemistry. The zinc is removed by sublimation — zinc boils at 907 °C, copper at 2,562 °C, so heating under vacuum takes 99 % of the zinc away and leaves the copper behind — followed by a resin column. Recovery is 94 % for the enriched material, and the two stages take about four hours each. The final product carries at most 0.01 % zinc-65 relative to copper-64.

Checked with the tools

Every calculation below uses the Decay calculator’s own maths with the recommended half-lives: copper-67 61.83 h, copper-64 12.701 h, zinc-65 243.93 d.

Step 1: the paper’s rounded half-lives. The tables give half-lives in days to two decimal places. For the long-lived nuclides that is harmless, but for the short ones it is not:

Nuclide Paper’s value In hours Recommended Off by
Cu-67 2.58 d 61.92 h 61.83 h +0.1 %
Cu-64 0.53 d 12.72 h 12.701 h +0.1 %
Zn-69m 0.57 d 13.68 h 13.76 h −0.6 %
Ni-65 0.11 d 2.64 h 2.5175 h +4.9 %

A 4.9 % error in a half-life of two and a half hours matters: correcting a one-day-old nickel-65 measurement back to the end of irradiation gives 0.00183 instead of 0.00135 of the original, a 36 % difference. Nothing in the paper’s conclusions turns on nickel-65, which it only calculates, but it is a good reminder to quote short half-lives in their own units rather than in days.

Step 2: what the eight-hour separation costs. Decay alone, before any chemistry:

What survives the separationWhat survives the separation02550751000204060Hours after the end of irradiationActivity left (%)8 h separationCu-67 (61.83 h)Cu-64 (12.70 h)Zn-65 (243.9 d)fibub.com
Figure 1. Decay curves from the Decay calculator’s own maths, with the recommended half-lives. The dashed line marks the end of the paper’s eight-hour separation: copper-64 has already lost a third of its activity, copper-67 less than a tenth.
At the end of the chemistry (8 h) Left
Cu-67 91.4 %
Cu-64 64.6 %
Zn-65 99.9 %

So the paper’s 1.23 kBq of copper-67 is 1.12 kBq when the chemistry finishes, or 1.06 kBq once its 94 % chemical recovery is applied too: decay costs 9 %, the chemistry 6 %. For copper-64 the balance flips — the same eight hours throw away 35 % of it, three times what any of their chemical steps lose, which is a quantitative argument for the shorter route (the sublimation alone took 20 min for the enriched sample) when copper-64 is the product. Their 6.61 kBq of copper-64 would be down to 4.27 kBq.

Step 3: the impurity grows by itself. Zinc-65 has a half-life of 244 days, so in any sample it stays put while the copper decays. The ratio therefore doubles every copper-67 half-life, 61.83 h, and every 12.7 h in a copper-64 product. Starting from the paper’s un-separated end-of-irradiation values at 52 MeV, zinc-65 is 0.236 % of the copper-67 activity at time zero and 1.52 % seven days later.

A long-lived impurity grows on its ownA long-lived impurity grows on its own0.20.511010002.557.51012.5Days after the end of irradiationZn-65 as % of the product1 %In the Cu-67 productIf the same Zn-65 sat with Cu-64fibub.com
Figure 2. The same amount of zinc-65 measured against each copper product, starting from the paper’s 52 MeV end-of-irradiation activities. Logarithmic scale.

The tool’s When will it fall to box answers the practical version of this directly: a product that leaves the lab at the paper’s 0.01 % zinc-65 limit reaches 1 % after 84 h if the product is copper-64, but only after 411 h (17 days) if it is copper-67. That gap is the shelf life, and it is set by the product’s half-life, not by the impurity’s.

Step 4: how carrier-free is it? The Decay calculator’s Specific activity card gives the carrier-free figures: 28,000 TBq per gram for copper-67 (a molar activity of 1.875 × 10¹⁸ Bq/mol, mean life 89.2 h) and 143,000 TBq per gram for copper-64. The paper’s product is not carrier-free: it calculates 0.13 atoms of stable copper-65 and 0.004 of copper-63 per atom of copper-67 at 52 MeV. Diluted by those, the molar activity becomes 1.654 × 10¹⁸ Bq/mol, or 88.2 % of carrier-free — and at 40 MeV, where the stable-copper ratios are 0.05 and 0.005, 94.8 %. Both are remarkably high for a neutron route, and that, not the raw yield, is what makes the method interesting for labelling antibodies.

Check Paper Our tool result
Cu-67 half-life 2.58 d 61.83 h (recommended), the paper 0.1 % high
Ni-65 half-life 0.11 d 2.5175 h; the paper 4.9 % high
Cu-67 at the end of an 8 h separation not given 91.4 % of 1.23 kBq = 1.12 kBq
Cu-67 after chemistry too (94 %) not given 1.06 kBq
Cu-64 at the end of an 8 h separation not given 64.6 % of 6.61 kBq = 4.27 kBq
Zn-65 at 0.01 % reaching 1 % of the product not given 84 h (Cu-64), 411 h (Cu-67)
Molar activity against carrier-free 65Cu/67Cu = 0.13 88.2 % at 52 MeV, 94.8 % at 40 MeV

How we made the graphs

Both charts and every number come from scripts/blog-figures/copper-67-64-accelerator-production-decay-losses.mjs in fibub’s public code. It calls decay (activity after a time interval), timeTo (how long until an activity falls to a given level), specific (decay constant, mean life, carrier-free specific and molar activity) and halfLifeS from src/lib/sci/decay.ts, the maths behind the Decay calculator.

From the paper: the end-of-irradiation activities, the half-lives as it prints them, the 8 h separation time, the 94 % chemical recovery, the 0.01 % zinc-65 limit and the stable-copper ratios. Half-lives for the calculations are the recommended NNDC/DDEP values already in the tool. Our assumptions: that the separation takes the full 8 h the paper describes, that nothing is lost except by decay and the stated chemistry, and that the stable-copper ratios apply to the separated product as calculated.

How we test the maths

On every change to fibub, tests/sci.mjs pins the decay maths against hand-checkable values, and the new tests/sci-tools/decay-calculator.mjs adds this paper’s numbers:

  • 370 MBq of fluorine-18 (109.77 min) must read 173.43 MBq two hours later, and correcting that back must return 370 MBq.
  • One half-life must leave exactly half of anything, to one part in 10¹².
  • New with this article: with the recommended half-lives, 8 h of decay must leave 0.914220 of a copper-67 activity and 0.646234 of a copper-64 one; 1.23 kBq of copper-67 must become 1124.49 Bq and 6.61 kBq of copper-64 must become 4271.6 Bq; a 100-fold rise in an impurity ratio must take 84.38 h against copper-64 and 410.78 h against copper-67; and the carrier-free specific activity of copper-67 must be 2.799 × 10¹⁶ Bq/g with a mean life of 89.20 h.

Check it yourself

On the decay calculator tool page, in the Decay correction card:

  1. Set Nuclide to Your own half-life…, then Half-life 61.83 with Unit h. Type Activity at the reference time 1.23 with Unit kBq.
  2. Set Reference date and time to 2026-11-24 08:00 and Wanted date and time to 2026-11-24 16:00, the eight hours of sublimation and column work.
  3. It reads about 1.12 kBq, with Fraction left 0.9142, Half-lives passed 0.129 and Decay constant λ about 3.11 × 10⁻⁶ s⁻¹.
  4. Now pick Nuclide Cu-64: half-life 12.701 h (PET) and type 6.61 kBq with the same two times: 4.27 kBq, Fraction left 0.6462. The same wait costs copper-64 five times as much as copper-67.
  5. Put 0.0661 (one per cent of the starting activity) in When will it fall to to see the shelf life question from the other side: Falls to that level after about 84 h, which is how long a 0.01 % zinc-65 impurity takes to become 1 %.
  6. In the Specific activity card, type Half-life 61.83 h with mass number 67 to get 2.8 × 10¹⁶ Bq/g and a molar activity of 1.88 × 10¹⁸ Bq/mol; divide by 1.134 for the paper’s stable-copper dilution at 52 MeV.

What researchers can use it for

  • Budget a radiochemical route by the clock: decide whether to shorten the chemistry or change the product (Decay calculator).
  • Convert published half-lives into the units you work in before using them for decay corrections, and see what the rounding costs (Decay calculator).
  • Work out a shelf life from an impurity limit, since a long-lived impurity’s share grows as the product decays (Decay calculator).
  • Compare a measured molar activity with the carrier-free ceiling to see how much stable carrier a route brings with it (Decay calculator).
  • Check whether activities this small are measurable at all with the counting statistics helper helper, and fit the gamma peaks they come from with the spectrum peak fitter.

The fine print

  • The paper’s activities are tracer scale (kilobecquerels from microamp beams). It argues for a 100 microamp upgrade; we have not scaled its yields, only applied decay to what it measured.
  • The eight hours is the paper’s own description of its two-stage process; a real production run would overlap steps.
  • We treat the zinc-65 to copper ratio as changing only by decay. In the real product the chemistry has already removed almost all the zinc, and the paper’s 0.01 % is its limit at the end of separation.
  • Carrier-free specific activity uses the mass number as the molar mass, which is the usual approximation and good to well under a per cent here.
  • This is laboratory and teaching arithmetic. It is not dosimetry, and it says nothing about what any of these activities would do in a patient.

Sources

  • Nagai, Y., Kawabata, M., Saeki, H., Motoishi, S., Hashimoto, K., Tsukada, K., Motomura, A., Ohta, A., Takashima, N., Hashimoto, S. et al. (2025), Production of 64Cu and 67Cu with accelerator neutrons by deuterons and their separation from zinc, Frontiers in Nuclear Medicine 5: 1657125, doi:10.3389/fnume.2025.1657125. Licence CC BY 4.0, checked in the Crossref record for the DOI, 2026-11-24. Values used here: deuterons on a 10 mm natural carbon target; 0.295 g of 64ZnO irradiated with 41 MeV deuterons at 0.11 microamps for 3 h, and 0.363 g of 68ZnO with 52 MeV deuterons at 0.379 microamps for 3 min; measured end-of-irradiation activities 1.23 kBq of Cu-67 and 2.9 Bq of Zn-65 (52 MeV), 0.383 kBq of Cu-67 (40 MeV) and 6.61 kBq of Cu-64 with 39.5 kBq of Zn-63 (41 MeV); calculated values within 20 % of measurement, with a 23 % calculated and 12 % experimental uncertainty; half-lives quoted as 2.58 d (Cu-67), 0.53 d (Cu-64), 244 d (Zn-65), 0.57 d (Zn-69m) and 0.11 d (Ni-65); sublimation at 500 to 600 degrees C removing 99 % of the zinc with 94 to 95 % column recovery, 93 min and 20 min sublimation times, about 4 h each for sublimation and chromatography; Cu-67 recovery 79 % (natural zinc) and 94 % (enriched 68Zn); Zn-65 to Cu-64 at most 0.01 % in the final product; calculated stable-copper companions 65Cu/67Cu 0.13 and 63Cu/67Cu 0.004 at 52 MeV, 0.05 and 0.005 at 40 MeV.
  • Half-lives used for every calculation here: NNDC (ENSDF) and DDEP recommended values as built into fibub's Decay calculator - Cu-67 61.83 h, Cu-64 12.701 h, Zn-65 243.93 d, Zn-69m 13.76 h, Ni-65 2.5175 h.

If you are an author or publisher and want a credit or a passage changed or removed, tell us and we will act quickly.