2068 kW from steel slag steam: rebuilding a waste-heat Rankine cycle from IF97 steam tables

A 2026 study recovers heat from steel slag and reports 2068 kW at 20.4 % thermal efficiency. We rebuild the whole cycle in fibub's steam tables from the paper's four stated conditions, matching its power, heat input and condenser duty.

Molten steel slag leaves the furnace at well over 1,000 °C and is usually cooled with water, throwing away the heat. A 2026 paper in Frontiers in Energy Research encloses the hot disintegration step in a cylindrical radiative receiver, raises steam from it, superheats that steam, and runs it through a turbine: 2068 kW of shaft power at 20.4 % thermal efficiency. The paper states four conditions for the cycle (0.2 MPa and 556.8 °C at the turbine, 0.004 MPa in the condenser, a 72 % efficient turbine) and three results (power, heat input and condenser duty). That is exactly the situation the steam tables are for: from the four conditions, the three results follow, and anyone can check them in a browser. For the equipment either side of the cycle, see the heat exchanger sizing calculator and the cost of energy calculator.

The paper in brief

Hot disintegration is the stage where slag at high temperature is broken up and cooled. The authors’ idea is to surround it with a cylindrical water-cooled receiver rather than a rectangular one: for the same receiver area they model a mean radiative heat-transfer rate of 17.54 MW against 13.83 MW, about 27 % higher, because a cylinder sees the hot bed from more directions.

That heat raises steam, which the paper then superheats to 556.8 °C while leaving it at only 0.2 MPa, about two atmospheres. The steam flow is 10,400 kg/h, the turbine is 72 % efficient, and the condenser works at 0.004 MPa, which corresponds to condensate at about 29 °C. Of the 10,127 kW of heat entering the water, 7,247 kW comes from the disintegration enclosure, 267 kW from an economizer and 2,613 kW from the superheater. The authors also run a small water-chemistry test, cutting equivalent hardness from 3.944 to 0.188 mmol/L with trisodium phosphate dosing, and are careful to say that the long-term behaviour of that treatment is untested.

Checked with the tools

Everything below comes from the steam tables, whose property functions are the IAPWS-IF97 industrial formulation, the standard used in power-plant engineering. We gave it only the paper’s four conditions, plus a pump efficiency of 75 % (our assumption; the paper gives the pump’s work, 0.66 kW, not its efficiency, and it is far too small to matter).

Step 1: the condenser temperature. IF97’s saturation line puts the boiling point of water at 0.004 MPa at 28.96 °C. The paper’s condensate leaves at 28.96 °C. The two agree exactly, which tells us the paper’s condenser is modelled as saturated, with no subcooling, and gives us the first cycle state for free.

Step 2: the cycle states. The tool’s rankine function puts the four corners of the cycle at:

State Pressure Temperature Enthalpy Entropy
1 pump inlet (saturated water) 0.004 MPa 28.96 °C 121.4 kJ/kg 0.4224 kJ/kg·K
2 boiler inlet 0.2 MPa 28.98 °C 121.7 kJ/kg 0.4227 kJ/kg·K
3 turbine inlet (superheated) 0.2 MPa 556.80 °C 3610.2 kJ/kg 8.6680 kJ/kg·K
4 turbine exit (still superheated) 0.004 MPa 207.31 °C 2894.1 kJ/kg 9.3580 kJ/kg·K
The slag-heat cycle on a temperature-entropy diagramThe slag-heat cycle on a temperature-entropy diagram020040060002468Entropy s (kJ/kg·K)Temperature (°C)saturation dome0.2 MPa (boiler)0.004 MPa (condenser)turbine (72 % efficient)fibub.com
Figure 1. The paper’s cycle drawn by the Steam tables tool’s own IF97 maths: water at 28.96 °C is pumped to 0.2 MPa, heated to 556.8 °C by the slag, expanded through a 72 % efficient turbine to 0.004 MPa, and condensed. The expansion ends 178 K above the boiling point, outside the saturation dome.

Step 3: the paper’s three results, recomputed. The turbine drops 716.08 kJ/kg (an ideal drop of 994.6 to an exit at 61.63 °C, of which the turbine takes 72 %), the pump adds 0.26 kJ/kg, the boiler and superheater add 3488.5 kJ/kg, and the condenser rejects 2772.7 kJ/kg. Multiply by the paper’s flow of 10,400 kg/h (2.889 kg/s) and the agreement is close to exact:

Check Paper Steam tables (IF97)
Condensate temperature 28.96 °C 28.96 °C (saturation at 0.004 MPa)
Cycle power 2068.4 kW 2067.9 kW (0.02 % apart)
Heat input 10,127 kW 10,078 kW (0.5 % apart)
Condenser duty about 8.01 MW 8.010 MW
Thermal efficiency 20.4 % 20.52 %
Feed-pump work about 0.66 kW 0.76 kW (at our assumed 75 % pump efficiency)

The only visible gap is the 0.5 % in heat input, and it has a simple explanation: 10,127 kW of heat at 3488.5 kJ/kg needs 10,451 kg/h of steam, not 10,400. Either the paper’s flow is rounded, or a little heat goes to blowdown or losses. A reader can decide which, because the arithmetic is now in the open.

Step 4: where the energy goes, and what it would take to do better. Three numbers from the tool explain this cycle completely:

  • The Carnot limit between 556.8 °C and 28.96 °C is 63.6 %. The cycle reaches 20.5 %, less than a third of it.
  • The turbine exhaust leaves at 207 °C, which is 178 K above the boiling point at 0.004 MPa. All of that superheat is thrown into the cooling water: the condenser duty is 8.0 MW against 2.1 MW of work.
  • The back work ratio is 0.037 %. The pump is free, which is the one luxury of a low-pressure cycle.

The reason is the 0.2 MPa. Superheating at two atmospheres gives the turbine a large temperature drop but a small pressure ratio, so the steam leaves hot. Figure 2 shows what the tool makes of the same cycle at higher boiler pressures, with the turbine inlet still at 556.8 °C: 23.2 % at 0.5 MPa, 25.1 % at 1 MPa, 27.0 % at 2 MPa and 31.4 % at 12 MPa. From the paper’s own 10,127 kW of heat, 2 MPa would give about 2,739 kW instead of 2,068 kW, a third more power from the same slag. Above about 8 MPa the exhaust finally becomes wet (quality 0.973 at 8 MPa, 0.948 at 12), which is where blade erosion starts to matter and reheat becomes worth its cost.

What the 0.2 MPa steam pressure costsWhat the 0.2 MPa steam pressure costs1520253035024681012Boiler pressure (MPa)Thermal efficiency (%)the paper's cycle, 20.5 %fibub.com
Figure 2. Thermal efficiency of the same cycle against boiler pressure, with everything else held as the paper has it. The dot is the paper’s 0.2 MPa design.

Two other sensitivities, for anyone planning such a plant: raising the turbine’s isentropic efficiency from 72 % to 80 % lifts the output from 2,068 kW to 2,298 kW, and letting the condenser warm from 0.004 MPa (28.96 °C) to 0.01 MPa (45.81 °C), which is what a hot summer or a fouled condenser does, drops it to 1,738 kW, a 16 % loss. In a steel works, condenser cooling is likely the easier of the two to get wrong.

How we made the graphs

Both charts and every number come from scripts/blog-figures/steel-slag-waste-heat-rankine-cycle-steam-tables.mjs in fibub’s public code. It calls rankine, dome, isobar, tsat and pT from src/lib/sci/if97.ts, the maths behind the steam tables: IF97 regions 1, 2 and 4 for the water, steam and saturation properties, the entropy inversions that give the isentropic turbine exit, and the cycle bookkeeping.

From the paper: 0.2 MPa, 556.8 °C, 0.004 MPa, a turbine efficiency of 0.72, a flow of 10,400 kg/h, and the three results we compare against (2068.4 kW, 10,127 kW, 8.01 MW). Our assumption: a pump isentropic efficiency of 75 %. Nothing is fitted: the cycle is solved once from the four conditions.

How we test the maths

tests/sci.mjs runs tests/sci-tools/steam-tables.mjs on every change to fibub. IF97 is a published standard with its own verification tables, so the checks are strict:

  • The region 1, 2 and 3 property values at the release’s verification points (for example 3 MPa and 300 K, 0.0035 MPa and 300 K, and the near-critical points) must match the published figures.
  • The saturation pressure and temperature must match the IAPWS equations and invert each other, and the properties are compared against the Python iapws package at about 100 points and five complete cycles.
  • New with this article: the paper’s cycle (0.2 MPa, 556.8 °C, 0.004 MPa, 72 % turbine, 75 % pump) must give a turbine work of 716.08 kJ/kg, a heat input of 3488.5 kJ/kg, a thermal efficiency of 20.52 % and a turbine exit at 207.31 °C, so the numbers printed above stay reproducible.

Check it yourself

On the steam tables page, in the Rankine cycle card:

  1. Set Boiler pressure to 0.2 MPa and Turbine inlet temperature to 556.8 °C.
  2. Set Condenser pressure to 0.004 MPa.
  3. Set Turbine efficiency to 72 % and Pump efficiency to 75 %.
  4. Put 2.068 into Net power (MW, for the flow rates).
  5. The headline reads Thermal efficiency 20.52 %. Net work is 715.8 kJ/kg (turbine 716.1 minus pump 0.262), Heat in is 3488.5 kJ/kg with 2772.7 kJ/kg rejected in the condenser, the Steam rate is 5.03 kg/kWh and the Carnot limit is 63.6 %.
  6. For 2.068 MW net reads 2.889 kg/s of steam (that is 10,400 kg/h, the paper’s flow), with a 10.08 MW heat input and 8.01 MW to the cooling water: the paper’s two other results.
  7. The state table shows the turbine exit at 207.3 °C and Turbine exit reads superheated steam, not a quality: there is no moisture at all in this turbine.
  8. Now change Boiler pressure to 2 and watch the efficiency climb to 27.04 % while everything else stays put.

What researchers can use it for

  • Audit a published cycle in two minutes. Four conditions fix the whole thing, so a power, a heat input and a condenser duty are checkable claims, as the table above shows.
  • Find the implied steam flow. Dividing a stated heat input by the IF97 heat per kilogram, as in step 3, catches rounded or inconsistent flow rates.
  • Rank the improvements before modelling them: pressure, turbine efficiency and condenser temperature each have a clear slope, and the tool gives all three in a minute.
  • Teach where the exergy goes. A 63.6 % Carnot limit against a 20.5 % cycle, with 178 K of superheat going into the cooling water, is a clearer lesson than any textbook diagram.
  • Size the equipment next: the receiver and the condenser with the heat exchanger sizing calculator, and the money with the cost of energy calculator.

The fine print

  • The 2068 kW is shaft power, as the paper is careful to say: generator and auxiliary losses are not modelled, so the exported electricity would be lower.
  • Our pump efficiency of 75 % is an assumption. At this pressure the pump work is 0.26 kJ/kg out of 716 kJ/kg, so any sensible value gives the same answers.
  • A simple Rankine cycle with no feedwater heating, no blowdown and no pressure drops is what the paper describes; a real plant would differ in each.
  • The 27 % gain for the cylindrical receiver and the water-treatment result are modelling and bench results in the paper, and neither is something a steam table can check.
  • Slag-heat recovery is intermittent by nature: hot disintegration is a batch process, and the steady-state cycle above is the best case, not an annual average.

Sources

  • Wu, H., Zhou, T., Bai, R., Xu, Z., Li, Y., Xia, B., Zhang, M. and Yang, H. (2026), An integrated waste heat recovery system for Rankine cycle power generation from the steel slag hot disintegration process, Frontiers in Energy Research 14, doi:10.3389/fenrg.2026.1965673. Licence CC BY 4.0, taken from Crossref (the journal page drops its copyright footer), checked 2026-11-24. Values used here: turbine inlet 0.2 MPa and 556.8 C; steam flow 10,400 kg/h; condenser 0.004 MPa with condensate at 28.96 C; turbine isentropic efficiency 0.72; feed-pump work about 0.66 kW; heat input 10,127 kW in total (7,247 kW from hot disintegration, 267 kW economizer, 2,613 kW superheater); condenser duty about 8.01 MW; modelled cycle power about 2,068 kW; thermal efficiency 20.4 %; the cylindrical receiver's mean radiative heat-transfer rate 17.54 MW against 13.83 MW for a rectangular one (about 27 % higher); water treatment with trisodium phosphate cutting equivalent hardness from 3.944 to 0.188 mmol/L.
  • IAPWS (2007), Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam (IAPWS-IF97), as implemented in fibub's src/lib/sci/if97.ts and checked against the release's own verification values and the Python iapws package.

If you are an author or publisher and want a credit or a passage changed or removed, tell us and we will act quickly.