A fuel cell at 2,000 m: checking the altitude air-density numbers

A 2026 study runs an 80 kW fuel cell system in Wuhan and on the Kunming plateau. The standard atmosphere calculator reproduces its air densities, its 0.822 and 0.669 density ratios and even its radiator and fan scaling.

A hydrogen fuel cell breathes. It needs a steady stream of air for its oxygen, and a second stream through a radiator to carry its waste heat away. Take the same system up onto a plateau and both streams thin out, so the stack loses power and the cooling fans have to work far harder. A 2026 paper in Energies measured exactly that: the same 80 kW fuel cell system tested in Wuhan, near sea level, and in Kunming, on the Yunnan plateau. Almost every altitude number in the paper can be rebuilt from first principles with the standard atmosphere calculator, and that is what this article does: the site densities, the density ratios the paper quotes, and the cooling and fan scaling it derives from them. For the aviation version of the same arithmetic see the density altitude calculator, and for the radiator itself the heat exchanger sizing tool.

The paper in brief

The authors ran a high-power proton-exchange-membrane fuel cell (PEMFC) system with liquid cooling for the stack and an air-cooled radiator, first in Wuhan (ambient pressure 101.3 kPa, taken at a representative 17 °C) and then in Kunming, whose test site sits at about 1,800 m and is labelled as the “2,000 m” condition (80.1 kPa, a representative 15 °C). Peak recorded stack power fell from 93.98 kW to 84.0 kW, maximum net power from 82 to 72 kW, and the time to load up from 10 to 90 % stretched from 24 to 32 seconds. The share of stack power eaten by the system’s own pumps and fans rose to 18.2 % at the 80 kW point.

To design a control strategy that adapts to altitude, the paper leans on the standard atmosphere: an agreed table of how temperature, pressure and density change with height on an average day. It quotes a density ratio of 0.822 at 2,000 m and 0.669 at 4,000 m, a pressure of 61.6 kPa at 4,000 m, an idealised radiator air-side heat-transfer coefficient falling to 92.5, 85.4, 78.8 and 72.5 % of its sea-level value at 1,000 to 4,000 m, and a fan power penalty of about 1.5 times at 2,000 m and 2.2 times at 4,000 m for the same air-side duty.

Checked with the tools

Everything below is a recomputation from the pressures and temperatures the paper states, using the 1976 standard atmosphere as fibub implements it. No measured curve from the paper is reproduced, and nothing is fitted.

The two site densities come out right. Air density is pressure divided by the gas constant for air times temperature. At Wuhan’s 101.3 kPa and 17 °C the tool gives 1.2163 kg/m³ (the paper says about 1.22); at Kunming’s 80.1 kPa and 15 °C it gives 0.9684 kg/m³ (the paper says about 0.97). Their ratio is 0.7962, which is the paper’s “about 0.80”. The paper also notes a sensitivity case with Wuhan at 25 °C: the tool then gives 0.8182, matching the 0.82 the paper reports for it. Against the sea-level standard density of 1.225 kg/m³, Kunming’s air is at 79.05 %, the paper’s “about 0.79”.

The paper’s standard-atmosphere ratios are exact. The tool’s 1976 standard gives a density ratio σ of 0.8217 at 2,000 m and 0.6689 at 4,000 m, against the paper’s 0.822 and 0.669; its pressure at 4,000 m is 61.66 kPa, against the paper’s 61.6. The paper’s idealised compressor pressure ratio for 4,000 m, 198.9 kPa ÷ 61.6 kPa = 3.23, becomes 3.226 with the tool’s pressure. Figure 1 puts both test sites on those curves.

But the plateau site is not a standard day, and that matters. Feed the measured 80.1 kPa into the tool’s Altitude from a pressure card and it answers a pressure altitude of 1,939 m, which is why labelling the campaign “2,000 m” is fair on pressure. The standard temperature at that height is 2.4 °C, while the site was about 15 °C: an ISA deviation of +12.6 °C. Warm air is thin air, so the real density, 0.9684 kg/m³, is 4.4 % below the 1.0127 kg/m³ the standard would give at the same pressure altitude. In aviation terms the tool reports a density altitude of 2,382 m: for anything that breathes air, the Kunming test was a 2,380 m day, not a 1,940 m one. A control law that interpolates on geometric altitude alone, as the paper’s sweep does, will under-correct on a warm plateau afternoon by roughly that 4 %.

Standard-atmosphere ratios, and where the two test sites sitStandard-atmosphere ratios, and where the two test sites sit0.60.8101e+32e+33e+34e+35e+3Altitude (m)Ratio to sea level80.1 kPa = 1939 mPressure δDensity σ (standard day)Site density ÷ 1.225fibub.com
Figure 1. Pressure and density ratio against altitude in the 1976 standard atmosphere, drawn with the Standard atmosphere calculator's own maths, with the paper's two test sites placed at the pressure altitude their measured ambient pressure implies.

Where the cooling numbers come from. The paper’s four idealised radiator percentages and two fan-power multipliers are given without their formula. The tool’s density ratio settles both at once (Figure 2):

Altitude Paper’s air-side coefficient σ^0.8 from the tool Paper’s fan power σ⁻² from the tool
1,000 m 92.5 % 92.53 % – 1.214
2,000 m 85.4 % 85.46 % 1.5 × 1.481
3,000 m 78.8 % 78.78 % – 1.815
4,000 m 72.5 % 72.49 % 2.2 × 2.235

So the air-side coefficient is simply the standard density ratio to the power 0.8, the classic turbulent convection exponent, and the fan penalty is the density ratio to the power −2. Both match to within a tenth of a point, from nothing but the altitude. Anyone extending the paper to another height can now do it in one line: at 3,000 m the air-side coefficient is 78.8 % of sea level and the fan needs 1.81 times the sea-level power for the same duty.

One stated number only makes sense in “normal” litres. The paper converts an air-flow reading of 5,600 L/min to 0.121 kg/s “at assumed standard density”. At the 1976 standard’s 15 °C that would be 0.1143 kg/s; at 0 °C and 101.325 kPa, the normal-litre convention used in flow meters, it is 0.1206 kg/s. The paper’s 0.121 is the second, so its flow readings are normal litres. At the site’s own 0.9684 kg/m³ the same volume flow is only 0.0904 kg/s, a quarter less, which is the reading that matters for stoichiometry.

The paper's cooling numbers are the density ratio to a powerThe paper's cooling numbers are the density ratio to a power10015020001e+32e+33e+34e+3Altitude (m)Relative to sea levelσ^0.8 (air-side coefficient)Paper, air-side %100 σ⁻² (fan power)Paper, fan powerfibub.com
Figure 2. The paper's idealised cooling numbers (black and grey dots) against two simple functions of the standard density ratio from the tool: σ to the power 0.8 for the air-side heat-transfer coefficient and σ to the power −2 for fan power.
Check Paper Standard atmosphere calculator
Density ratio at 2,000 m and 4,000 m 0.822, 0.669 0.8217, 0.6689
Pressure at 4,000 m 61.6 kPa 61.66 kPa
Wuhan and Kunming air density about 1.22, 0.97 kg/m³ 1.2163, 0.9684 kg/m³
Site density ratio about 0.80 (0.82 at 25 °C) 0.7962 (0.8182)
Kunming against sea-level standard about 0.79 0.7905
Pressure altitude of 80.1 kPa labelled 2,000 m 1,939 m, density altitude 2,382 m
Radiator air-side coefficient 92.5 / 85.4 / 78.8 / 72.5 % σ^0.8 = 92.53 / 85.46 / 78.78 / 72.49 %
Fan power for the same duty 1.5 ×, 2.2 × σ⁻² = 1.481, 2.235
5,600 L/min as a mass flow 0.121 kg/s 0.1206 kg/s at 0 °C; 0.1143 at 15 °C; 0.0904 at the site

How we made the graphs

Both charts and every number above come from scripts/blog-figures/fuel-cell-plateau-air-density-ratio-standard-atmosphere.mjs in fibub’s public code. It calls atmosphere, pressureAltitude, densityAltitude and stdTP from src/lib/sci/eng-atmos.ts, the maths behind the standard atmosphere calculator, which builds the 1976 standard from its defining layer temperatures and lapse rates rather than from a printed table.

From the paper: the two ambient pressures, the two representative temperatures, the quoted density ratios, the 4,000 m pressure, the radiator percentages, the fan multipliers and the 5,600 L/min flow. Our own additions: the exponents 0.8 and −2 (we fitted nothing, we simply tried the two standard exponents and they land on the paper’s points), and treating both sites’ stated temperatures as the air temperature at the measurement.

How we test the maths

tests/sci.mjs runs tests/sci-tools/standard-atmosphere.mjs on every change to fibub. It pins the atmosphere against an independent Python script that integrates the hydrostatic equation with SciPy from the same defining constants:

  • Sea level must give exactly 288.15 K and 101,325 Pa, a density of 1.225 kg/m³, a speed of sound of 340.294 m/s and a viscosity of 1.78938 × 10⁻⁵ Pa·s.
  • Every layer boundary of the standard must come out: 22,632.06 Pa at 11 km, 5,474.889 Pa at 20 km, 868.0187 Pa at 32 km, down to 3.956420 Pa at 71 km.
  • The SciPy integration must be matched to 2 parts in 100,000 at eight heights from −2,000 m to 71,000 m, for example 54,048.3 Pa and 0.736428 kg/m³ at 5,000 m.
  • Pressure altitude must invert the pressure in every layer (70,000 Pa gives 3,012.18 m), and a density of 1.0 kg/m³ must give a density altitude of 2,064.29 m.
  • New with this article: the plateau case. A pressure of 80,100 Pa must give a pressure altitude of 1,938.9 m; 80.1 kPa at 15 °C must give 0.96840 kg/m³ and a density altitude of 2,382.1 m; and the standard density ratios at 2,000 m and 4,000 m must be 0.82168 and 0.66885, so that σ^0.8 reproduces the paper’s 85.46 % and 72.49 %.

Check it yourself

On the standard atmosphere calculator:

  1. In the Altitude card, type 2000, leave Height type on Geometric (tape-measure height) and ISA deviation ΔT on 0. It reads 275.15 K (2 °C), 79,501 Pa, 1.007 kg/m³, and under Ratios to sea level, σ = 0.8217 with δ = 0.7846. Those are the paper’s 0.822 and its 2,000 m condition.
  2. Change ISA deviation ΔT to 12.6 (the plateau’s warm day). Temperature becomes 287.75 K (14.6 °C), the pressure does not move, and density falls to 0.9625 kg/m³ with a Density altitude of 2,442 m.
  3. In Altitude from a pressure, type 80.1 and set Pressure unit to kPa. It answers Pressure altitude 1,939 m, and notes the standard temperature there as 275.55 K.
  4. In Density altitude at an airfield, set the field elevation to 1800 m, Altimeter setting QNH to 995.9 hPa (the setting that gives 80.1 kPa at that elevation) and Outside air temperature to 15 °C. It reads Density altitude 2,382 m, with a pressure altitude of 1,939 m, an ISA deviation of +12.6 °C and an Air density of 0.9684 kg/m³, 79.1 % of sea-level standard: the paper’s 0.97 kg/m³ and 0.79.
  5. For the cooling numbers, read σ at 1,000, 2,000, 3,000 and 4,000 m (0.9075, 0.8217, 0.7422, 0.6689) and raise each to the power 0.8 for the air-side coefficient, or to the power −2 for the fan power.

What researchers can use it for

  • Convert a measured ambient pressure into an altitude that other people can compare with, instead of a nominal site label: 80.1 kPa is a pressure altitude of 1,939 m anywhere in the world.
  • Separate the pressure effect from the temperature effect on any air-breathing machine. The ISA deviation box shows how much of a density loss is height and how much is a hot day; here it is 4 % of extra loss that a height-only lookup misses.
  • Correct volumetric flow readings to a mass flow at the real site state, and work out which reference state someone else’s “standard litres” used.
  • Scale a radiator or fan to another altitude with the density ratio and the right exponent, then size the real exchanger with the heat exchanger sizing tool.
  • Plan a high-altitude test campaign: tabulate pressure, density, viscosity and speed of sound every 500 m, so compressor maps and Reynolds numbers can be corrected before the trucks leave.

The fine print

  • We use the 1976 standard atmosphere. The paper does not name its standard, but its quoted ratios match it to three decimals.
  • The paper gives representative temperatures, not logged ones, and says so. Every density here therefore carries that uncertainty; 1 K changes a density by about 0.35 %.
  • The exponents 0.8 and −2 are our reading of the paper’s idealised cooling numbers, not values it states. They fit all six of its points to within 0.1 point, but a different pair of assumptions could come close.
  • Nothing here checks the paper’s fuel cell measurements, its control strategy or its thermal model. Only the atmosphere and the scaling that follows from it are checked.
  • Humidity is ignored, as in the paper. Moist air is slightly less dense than dry air at the same pressure and temperature.

Sources

  • He, S., Wang, G., Liu, Y., Zhou, J., Li, Y. and Liu, J. (2026), Experimental Characterization and Model-Based Altitude-Adaptive Liquid-Air Coupled Thermal Management of a High-Power PEMFC System in Plateau Environments, Energies 19(21): 5299, doi:10.3390/en19215299. Licence CC BY 4.0, taken from the Crossref record (the MDPI page's rights metadata says CC BY 3.0), checked 2026-11-24; the Crossref record carries no correction or retraction. Values used here: Wuhan at about sea level, 101.3 kPa, a representative 17 °C and about 1.22 kg/m³; Kunming, site about 1,800 m and labelled 2,000 m, 80.1 kPa, a representative 15 °C and about 0.97 kg/m³, a site density ratio of about 0.80 and about 0.79 of the sea-level standard; standard-atmosphere density ratios of 0.822 at 2,000 m and 0.669 at 4,000 m with 61.6 kPa at 4,000 m; an idealised radiator air-side coefficient of 92.5, 85.4, 78.8 and 72.5 % of sea level at 1,000 to 4,000 m; fan power about 1.5 times at 2,000 m and 2.2 times at 4,000 m for the same air-side duty; an idealised compressor pressure ratio of 3.23 at 4,000 m against 2.48 reached in the tests; peak stack power 93.98 kW in Wuhan against 84.0 kW in Kunming; an air flow reading of 5,600 L/min taken as 0.121 kg/s.
  • US Standard Atmosphere 1976 (the defining layer temperatures, lapse rates and constants) and Sutherland's law for viscosity, as implemented in fibub's own code.

If you are an author or publisher and want a credit or a passage changed or removed, tell us and we will act quickly.

Tools in this article