Home / Science / Chemistry / Organic chemistry / TLC Rf calculatorTool #91

TLC Rf calculator: tap spots on a plate photo for Rf values and flash column volumes

Open a photo of a TLC plate, tap the baseline, solvent front and spots, and get each spot's Rf, its lane, the column volumes it needs on a flash column and how well neighbouring spots separate. Or type measured distances.

Keep it one tap away for everyday use.

Bookmark TLC Rf calculator?

Press Ctrl + D now. Your browser opens its own bookmark box, where you choose the name and folder.

  1. Photo
  2. Tap spots
  3. Rf values
  4. Column
Nothing is uploadedWorks offline once open

Plate photo

Measured distances

Rf = distance moved by the spot ÷ distance moved by the solvent, both from the baseline, measured to the centre of the spot. Values between 0.2 and 0.8 are the most reliable. On a flash column with the same eluent a compound needs about 1/Rf column volumes, so Rf 0.25 to 0.35 for the wanted compound is the usual aim.

Download

What it does

Thin-layer chromatography (TLC) is the quickest check in an organic lab: has the starting material gone, is there one product or three, which eluent will work for the column? Each spot is described by its retardation factor, Rf = distance moved by the spot ÷ distance moved by the solvent, both from the baseline.

  • From a photo. Open a picture of your plate (taken under a UV lamp or after staining), tap the baseline, the solvent front and the centre of each spot. The tool marks them on the photo, groups the spots into lanes, and lists each Rf. The photo is never uploaded; it stays on your device.
  • From a ruler. Type the distance to the solvent front and to each spot in millimetres.
  • Column volumes. On a flash column packed with the same silica and run in the same eluent, a compound comes off after about 1/Rf column volumes (CV). Spots with Rf 0.25 to 0.35 are the usual aim.
  • Separation. For the closest pair of spots it gives ΔRf and ΔCV. A ΔCV of 1 or more usually separates on a flash column; below that, change the eluent.
  • Same compound? Spots within 0.02 of each other in different lanes are pointed out, which is what a co-spot lane is for.
  • Advice per spot: barely moved (more polar eluent), near the front (less polar eluent), or good for a column.

How to use it

  1. Press Example plate to see how it works, or open your own photo. Hold the plate upright in the picture, baseline at the bottom, so distances are measured straight up the plate.
  2. Baseline is selected first: tap the pencil line where you spotted. Then tap the solvent front. The tool moves on to Spots.
  3. Tap the centre of each spot. Use Undo, or Remove in the table, to fix a mistake. You can switch back to Baseline or Front to move a line.
  4. Download the marked photo with the table as a PNG, PDF or Word file for your notebook.

Worked example

The example plate has three lanes: starting material (SM), a co-spot, and the reaction mixture, with the front 480 pixels above the baseline. The starting material sits at Rf 0.36, the product at 0.58 and a by-product at 0.12. The co-spot lane shows the product spot is not starting material. Starting material and product need 2.8 and 1.7 column volumes, a ΔCV of 1.05, so a flash column in this eluent should separate them.

With a ruler: the front 52 mm from the baseline and spots at 18 and 32 mm give Rf 0.35 and 0.62.

Questions

Should I measure to the top or the middle of a spot? The centre (the darkest point). Streaky or very large spots mean the plate was overloaded.

Why does my Rf change from day to day? Rf depends on the eluent mixture, plate type, chamber saturation, temperature and humidity. Compare with a reference spot on the same plate.

Is my photo uploaded? No. It is opened in your browser and never leaves your device.

Last updated 2026-11-08.

Change log for TLC Rf calculator

  1. Add the TLC Rf calculator with plate photo marking (#91) Details on GitHub

Every change to fibub

Related tools

Molar mass calculator #78 Type any formula, including brackets, hydrates, isotope labels and charges, for its molar mass, exact mass, percentage of each element, and a grams, moles and particles converter. Reaction equivalents table #85 The reagent table of a lab notebook: molar masses from formulas, equivalents, density, purity and solution molarity, giving the mass to weigh or volume to measure for every reagent, and the theoretical and percent yield. Chromatography calculator #86 Resolution, retention factor, selectivity, plate number and HETP for two peaks, the plates needed for a target resolution, and moving an HPLC method to a shorter, narrower column (flow, injection, gradient times, USP <621> L/dp check). Graph digitiser #26 Open a picture or screenshot of a graph, mark the axes, then click the points or let it trace a curve by colour. Get the numbers as a table to copy or download. The image never leaves your device. NMR solvent and impurity peak checker #106 Paste a peak list (even a journal-style one) and see which peaks are residual solvent, water, grease or common lab solvents such as ethyl acetate, DCM and ether, in CDCl₃, DMSO-d₆, CD₃OD, D₂O and six more, for ¹H and ¹³C. IR spectrum band finder #109 Type the peaks of an infrared spectrum, or open the spectrum itself, and see which bonds and functional groups each band could belong to: carbonyls, O–H, N–H, nitriles, aromatics and more, with groups that need several bands checked together and a searchable band table.